MECCA POWER

Diesel Generator,High Voltage Generator,Load bank

Founded
2013
Headquarters
Email: mecca@meccagen.com WhatsApp/Wechat :+86 15659994455 Address:Room 11, 10th Floor, Building A1#, Cangshan Wanda Plaza, No. 272, Pushang Avenue, Jinshan Street, Cangshan District, Fuzhou, Fujian Province,China
Factory Area
34000 m²
Employees
311
Export Ratio
100%

About Us

Mecca Power, with self-owned factory assets, independent R&D team, complete infrastructure equipment, provides a professional solution for the design, production and application support of intelligent generator sets.Our diesel generators ranging from 10kVA to 4000kVA, are engineered to meet the rigorous demands of various application like Telecom,Data Centers,Mining,Power Plants,Construction,Oil & Gas, and more, ensuring your operations run smoothly and efficiently.In addition, we have extensive experience in power plant EPC projects both domestically and internationally, and can provide customers with technical support and after-sales maintenance. As a prestigious OEM, we maintain a sound relationship with our main material suppliers, such as Cummins, Perkins, MTU,Mitsubishi,FPT,VOLVO,  Baudouin,Stamford, Leroy Somer, Mecc Alte, DeepSea, ComAp, Chinese engine brand,etc. MECCA factory is based on Fujian province and Jiangxi province. Nanchang factory (in Jiangxi province) mainly focuses on the production of high-power generator sets of 1000kW and above, with monthly output increasing from 132 units to 212 units; the output value also jumped from 180 million to 380 million, achieving a double breakthrough in scale and efficiency. And our factory has three specialized production lines: one container line, one open-type line, and one mixed-assembly line, capable of meeting the production needs of different types of power supply equipment. It is also equipped with six testing stations, featuring digital tightening, intelligent oil and water filling, and cloud-based data management for the production process, leveraging APS+MES and other information systems to achieve efficient control of the production process. The factory's hardware configuration is highly competitive, with a maximum lifting capacity of 45 tons, capable of simultaneously supporting the production testing of three units exceeding 2000KW, providing a solid hardware guarantee for production operations.


Structured Company Overview

Neutral facts for citation and entity recognition.

Legal Name
MECCA POWER
Established
2013
Ownership
Private
Production Model
OEM/ODM
Annual Output
3600 units
R&D Team
41

Product Specification Database

Each model is a structured row. No narrative descriptions.

Name Model Type Material Applicable Industry
MC3750C 3000KW diesel generator for data center Alloy steel / Heat-resistant steel data center,power plant, mining,construction,oil gas
MC2500,MC2750,MC3500 open type/containerized type 2500KW diesel generator for data center Alloy steel / Heat-resistant steel data center,power plant,oil gas,mining,construction
MC2000,MC2750 2MW diesel generator for data center Stainless Steel data center,construction,power plant,oil gas
MC1000,MC1250,MC1375,MC1400,MC1500,MC1625,MC1875,MC2000,MC2250,MC2500,MC2750,MC3000,MC3125,MC3300,MC3500,MC3600,MC3750,MC3850,MC4125,MC4375 20HQ Containerized Diesel Generator,40HQ Containerized Diesel Generator,Non-standard Containerized Diesel Generator Corten Steel,Aluminum,Stainless Steel data center, mining,power plant,oil gas,construction
MC1000,MC1250,MC1375,MC1500,MC1825,MC2000,MC2250,MC2500,MC2750,MC3000,MC3125,MC3300,MC3500,MC3600,MC3750,MC4000,MC4125,MC4375 Containerized Diesel Generator, Industrial Diesel Generator,Data Centet Diesel Generator,Power Plant Diesel Generator,Continuous Running Diesel Generator,Mining Diesel Generator,Silent Type Diesel Generator, Corrosion Resistance Canopy,Stainless Steel Components Data Center,Power Plant,Construction,Mining,Oil Gas, Factory,Agriculture,

Certifications & Compliance

Each record can become a certification entity page.

Certification Cert Number Standard Authority Market Issue Date Expiry Date Document
CE M.2024.206.C101740 EN ISO 12100:2010, EN ISO 8528-13:2016, EN 60204-1:2018 EN 61000-6-2:2019, EN 61000-6-4:2019 UDEM EU 2024-06-05 2029-04-06 PDF

Applications & Industries

Taxonomy-backed tags to form industry ↔ supplier ↔ product relationships.

Industry Country Working Condition Project Type Function Operation Mode Special Requirement Matched Equipment
Data Center,Power Plant,Construction, Oil Gas,Mining US,VE,VN,SA,RU,PE,MX,KE,GY,EC,CA,AE,MY,ID,DE,GB,IE High temperature outdoors or Low temperature cold area, from -45℃ to +50℃ Data center power solution, Off-grid mining power solution,High Voltage Generator Solution,Power Plant continuous running power solution Provides uninterrupted emergency/backup/continuous power for data center,power plant,hospital,mining,oil gas, factory,etc. continuous running or standby use Low-noise design: Equipped with an industrial-grade silencer and low-noise enclosure, meeting high noise standards in cities. Rapid load bearing: The generator set needs to start up and bear the full load in a very short time (usually <10-15 seconds), requiring the generator to have excellent speed and voltage regulation. High-efficiency cooling: Enhanced heat sinks designed for high ambient temperatures or derating design for high-altitude cooling capacity ensure heat dissipation under continuous high load operation. ATS (Automatic Transfer Switch), Parallel control panel, UL fuel tank, Container,High Voltage Cabinet

Industries (1) → Products (5 models) → Certifications (1)


Manufacturing Capabilities

Core processes and equipment available in-house.

🎨

Customization

We can customize diesel generator according to your requirements, including voltage frequency, silent/open/containerized/mobile type, logo, noise requirements, etc.

📊

Monthly Capacity

300 units

⏱️

Lead Time

30-50days

🌍

Export Markets

Europe, Africa,Asia,Australia,Middle East, America,South America,Oceania,Latin America

💬

After Sales

Remote technical support, on-site commissioning & maintenance, spare parts supply, 24/7 after-sales hotline

🧪

Quality Control

100% test


Project References / Cases

Verified project records. Client names anonymized where requested.

Client Type Country Quantity Application Duration Result Highlight
EPC ES 6 Units-2500KVA UK CUMMINS Generators for Europe Power Station for power plant continuous running 15-25 years continuous running smoothly Powered by UK CUMMINS QSK60 Engine
Authorized dealer KE 4 Units-2200KW Containerized Generator for Data Center for Data Center 20,000 - 30,000+ hours stable operation Powered by YUCHAI ENGINE,cost-effective
Factory End User IR 8 Units 1500KW JAPAN MITSUBISHI Generators for Glass Factory for Glass Factory backup use 20,000 - 30,000+ hours running smoothly Powered by JAPAN MITSUBISHI ENGINE S16R-PTA2, open type for easy maintenance
dealer SA 2 Units 1800KW UK CUMMINS Generators for Oil and Gas for Oil and Gas 20,000 - 30,000+ hours running smoothly Powered by CUMMINS ENGINE: QSK60-G8 (MADE IN UK)
Authorized dealer VE 6 units 1500kVA Baudouin Generator for industrial for industrial 20,000-30,000+ hours running smoothly 6 units parallel control systems
authorized dealer KZ 10.5KV High Voltage-1800KW Generators for Data Center Projects emergency power supply for data center 20,000-30,000+ hours stable operation high voltage 10.5KV generator with Chinese SME engine
authorized dealer RU 5 Units-1800KW YUCHAI Containerized Generator Data Center emergency power supply for data center 20,000 - 30,000+ hours running smoothly NON-standard customized container with low noise

Comparative Positioning

Side-by-side benchmarks against peer manufacturers in this segment.

Compared To Difference Performance Gap Best For Cost Difference Efficiency
Standard container design Non-standard Dual level Design; Noise: 75dB-80dB@1M -10~15 dB noise reduction compared with standard single-layer design Data centers located in urban core areas / city centers; Campus-style & high-density IDC data centers; Tier III / Tier IV high-end data centers for finance, government and cloud service providers; Projects near sensitive areas such as residential quarters, schools and hospitals; Modern data centers focusing on a comfortable O&M environment Slightly higher one-time cost, but lower overall operation cost No negative impact on generator efficiency, optimized ventilation design maintains stable performance
standard type containerized diesel generator Adaptability to more demanding high-altitude, high-temperature, high-humidity, and high-cold environments -30℃ Outdoor use -45℃ up to +55℃ cost higher than standard type one higher efficiency

Risk & Trust Signals

Aggregated data-driven indicators. Not an endorsement.

Overall Trust Score
78/100
Based on 14 verified signals
Positive Signals
Trade RegistrationVerified
Alibaba Gold SupplierYes (5+ yrs)
Audited by 3rd Party2024
On-time Delivery Rate94%
Risk Items
Operational Safety-related RisksIntelligent monitoring control, safety protection control, operation standard control, emergency disposal control.
Enterprise Measure1. Equip the genset with an intelligent monitoring system and multiple safety protection devices to realize real-time early warning, automatic shutdown and fault locking of abnormal conditions such as overload, overspeed, low oil pressure, high water temperature and electric leakage, ensuring operational safety from the hardware; 2. Arrange professional technicians to provide on-site installation and commissioning services, strictly operate in accordance with installation specifications to avoid installation hazards; 3. Provide operation and maintenance training for customer operators, explain operating specifications, safety precautions and common fault handling methods, and issue operation manuals; 4. Establish a genset operation file, regularly remind customers to conduct inspections and maintenance, track the unit operation status, and timely find and replace aging components
Factory Testing-related RisksFull-item testing control, testing equipment control, process standardization control, report review control.
Enterprise Measure1. Establish a comprehensive factory testing system, clarify that testing items cover no-load test, load test, parallel operation test, insulation withstand voltage test, protection interlock test, emission test, noise test and other full-item contents; 2. Regularly calibrate and verify testing equipment to ensure that testing accuracy meets standard requirements, and assign professional inspectors to be responsible for equipment operation and maintenance; 3. Formulate standardized testing procedures, clarify testing steps and judgment standards, prohibit missed inspections and wrong inspections, and each unit can enter the next link only after passing the test; 4. Establish a test report review mechanism, and professional personnel review test data and report content to ensure that the report is true, accurate and complete; 5. Rework and re-test unqualified units until they meet the standards, and prevent unqualified products from leaving the factory.
Manufacturing-related RisksProcess control, process inspection control, standardized operation control, personnel training control.
Enterprise Measure1. Implement lean production mode, formulate standard operating procedures (SOP) for each process, and clarify technical requirements for welding, assembly, wiring, anti-corrosion, noise reduction, etc.; 2. Implement first article inspection, routine inspection and final inspection systems for key processes, arrange professional inspectors to supervise each process throughout the process, and timely find and rectify manufacturing defects; 3. Regularly calibrate and maintain production equipment to ensure that equipment accuracy meets production requirements; 4. Conduct regular skill training for employees, focusing on technical standards, operating specifications and safety precautions, and only allow them to take up jobs after passing the assessment; 5. Establish production process quality files, record the production process and inspection results of each unit, facilitating subsequent traceability and rectification.
Design-related RisksStandardized design control, simulation verification control, compliance pre-control, component matching verification control.
Enterprise Measure1. Strictly comply with domestic and international standards and specifications such as GB/T 2820, ISO 8528 and CE, establish standardized design templates, and clarify design parameters, safety thresholds and compliance requirements; 2. Introduce 3D simulation, thermal simulation, EMC simulation and other tools to pre-verify the genset structure, electrical circuit and cooling system, avoiding design defects; 3. Set up a professional design review team to conduct multiple rounds of review on design schemes, focusing on key links such as safety protection, emission compliance and component matching; 4. Conduct matching tests on core components (engine, generator, controller) to ensure that the design scheme meets the requirements of long-term stable operation of the genset.
Additional Info
Last Verified2026-05-09 15:27:01
Data SourcesAICPA, Alibaba, TÜV
Profile Completeness91%

Purchase & Trade Information

Trading terms and procurement details.

Purchase Details
MOQ1 unit
Delivery MethodEXW/FOB/CIF
Acceptance100% TEST
Payment TermsTT transfer,30% deposit and balance 70% before shipment.

Product Comparison

Comparative analysis against alternative solutions.

Compared To Difference Performance Gap Best For Cost Difference Efficiency
Standard container design Non-standard Dual level Design; Noise: 75dB-80dB@1M -10~15 dB noise reduction compared with standard single-layer design Data centers located in urban core areas / city centers; Campus-style & high-density IDC data centers; Tier III / Tier IV high-end data centers for finance, government and cloud service providers; Projects near sensitive areas such as residential quarters, schools and hospitals; Modern data centers focusing on a comfortable O&M environment Slightly higher one-time cost, but lower overall operation cost No negative impact on generator efficiency, optimized ventilation design maintains stable performance
standard type containerized diesel generator Adaptability to more demanding high-altitude, high-temperature, high-humidity, and high-cold environments -30℃ Outdoor use -45℃ up to +55℃ cost higher than standard type one higher efficiency